psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114

Normal 410a pressures. What should my normal operating pressures on 410a systems be?. Btw ... pressures with Temperature Pressure chart to obtain required pressures Notes:. if i ...

Cooling index merupakan tingkat pendinginan freon. Flammability merupakan tingkat kemudahan terbakar freonnya. Dari tabel tekanan freon R32, R22, dan R410a, bisa disimpulkan beberapa hal, yakni sebagai berikut. Freon R32 jauh lebih ramah lingkungan dibanding freon R410a karena tingkat GWP-nya lebih rendah dibandingkan freon R22 …

Saturation Pressure-Temperature Data for R410A (psig)* *Red Italics Indicate Inches of Mercury Below Atmospheric PressureWhat are normal operating pressures for 410A in cooling mode? During air conditioning mode, the pressure on the vapor line of an R-410A system will be …Jan 16, 2023 · What are 410a pressures on a 95 degree day? The typical 410a pressures on a 95 degree day are as follows; Liquid pressure: 296.4 psi. Vapor pressure: 295.5 psi. See all other pressures for R410 on different temperatures of the day from -49°F to 150°F below. R410a Pressure Chart High and Low Side Product Information. FreonTM 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. FreonTM 410A has higher cooling capacity and …base-valve service ports. Run system at least 10 minutes to allow pressure to stabilize. 2. For best results, temporarily install a thermometer on the suction line near the compressor. The thermometer should be located within 4” to 6” of the compressor. Ensure the thermometer makes adequate contact and is insulated.Jul 20, 2021 · An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ... Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000.January 9, 2017. A restricted metering device — thermostatic expansion valve or TXV — can cause a number of symptoms in a system. Here are the ways a TXV can become restricted: Wax buildup in the valve because the wrong oil was used in the system; Sludge from the byproducts of a compressor burnout; Partial TXV orifice freeze-up from ...

Jun 7, 2021 · r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. It's been some time since we last published a new article on these important HVAC system measurements. David Richardson provides a fresh review of the procedures.Refrigerants - Pressure vs. Temperature Charts Temperature and pressure chart for refrigerants R22, R410A, R12, R134A, R401A, R409A, R502, R404A, R507A, R408A and R402A. Refrigerants - Saturation Pressures vs. Temperatures Temperature and pressure diagram for constant boiling refrigerants - imperial and SI units. Triple Points SubstancesMay 26, 2012 · It is stamped 4lbs 15oz. for the manufactures charge of 410A. 4. Last check by the tech from the company that installed it before going out of warranty was High side 275 psi, high side temp 70F, Low side psi was 115 Low side temp 50. This calculates to Super Heat of 12 more or less. Generally, you will see normal superheat (8°-14°) on a system with heat mode TXV, and the subcooling will generally be a bit higher than usual, especially when measured outside. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system.Turn the thermostat to cool and set the target temperature at least 10 degrees lower than the indoor temperature. Let the system operate for at least 10 minutes to let pressures equalize. Record the suction line pressure. Use a temperature measuring device to measure the temperature of the suction line.

Per the National Institutes of Health (NIH) National Institute on Aging, normal blood pressure for most adults is defined as a systolic pressure of less than 120 and a diastolic pressure of less ...They recorded a 245 psi Head pressure and 115 suction pressure on my installation receipt. He also wrote "10 degrees subcool" on the receipt, which I don't see how that is possible when a 245 psi equals 83 degrees on an R-410a P/T chart. The small, copper liquid line (when measured near the compressor valve) doesn't seem to heat up …January 9, 2017. A restricted metering device — thermostatic expansion valve or TXV — can cause a number of symptoms in a system. Here are the ways a TXV can become restricted: Wax buildup in the valve because the wrong oil was used in the system; Sludge from the byproducts of a compressor burnout; Partial TXV orifice freeze-up from ...R410A Pressure-Temperature Chart Liquid. Vapor: Liquid: Vapor Liquid: Vapor Liquid: Vapor-49; 5.5; 5.4-45 1: 49.7 49.5-17.2 51: 145.8 145.2: 10.6 101: 323.1 322.1: 38.3-48; 6 5.9-44.4 2; 51.1 50.8 ... Pressure Temp (°C) Temp (°F) Pressure Temp (°C) Temp (°F) Temp (°C) Pressure Temp (°F) Pressure Temp (°C) Created Date:by ziauddin khan khan , Electrical and supervisor , Majal Service Company. …See more. hi, anyone familar with R410A. For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 ...What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. What is the normal discharge ...

White pill an 627.

These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.™ 410A Refrigerant (R-410A) Piping Guide for Freon™ 410A (ENG Units) Technical Information Suction Line Size—Evaporator to Compressor ... (62 through 38 psig) Suggested Allowable Pressure Drop in psig = 2 °F 4.6 lb (2 °F) 3.5 lb (2 °F) 2.5 lb (2 °F) Equivalent Suction Line Length—Feet System Capacity Btu/Hr System Capacity Tons/Hr ...Saturation Pressure-Temperature Data for R410A (psig)* *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure™ 410A Refrigerant (R-410A) 0 0 20 40 60 80 Temperature (°F) 100 120 140 R-22 R-410A 100 200 300 400 500 600 700 Product Information Freon™ 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. Freon™ 410A has higher cooling capacity and operating pressures than R-22 for new equipment specifically designed ...

R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol. R22 gas cylinder identification: light green. R2 status: no longer in active use, replaced with R458A. The human heart creates a pressure within the circulatory system every time it beats. Some people experience periods where their blood pressure is too high or too low. When blood Maintaining normal blood pressure levels is an important part...Suction Pressure / EVAP DTD Rule of Thumb Another common old school rule of thumb is suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient.barg. Used to describe R410A gauge pressure; it's commonly referred to as "2-bar gauge pressure" in HVAC literature. psig. Pounds Per Square Inch (psig) is most commonly used to express pressure levels at a specific temperature for R410A refrigerant. In universal units, 1 psi equals to about 6895 N/m 2.Freon™ 410A is intended for use in new air conditioning applications that have traditionally been serviced by HCFC-22. Many other applications are also possible, such as medium- and low-temperature refrigeration. Due to the significantly higher pressures that Freon™ 410A exhibits compared to HCFC-22, a typical compressor designedOnline R454B pressure temperature chart spanning from -40°F to 150°F temp. Printable PDF version of R454B PT chart you can take with you on the job. There are several brand names for R454B: Opteon XL41, Solstice 454B, and Puron Advance. This is a blend of R32 (68.9%) and R1234yf (31.1%). It has a very low boiling point of -59.5°F (-50.9°C).Another significant difference between R-410A and R-22 is its saturation pressure range. R-410A has a higher pressure range curve than R-22. Remember, R-410A is a near azeotrope that is subject to some fractionation. At any specific temperature it has a higher vapor pressure than R-22 when saturated. R-410AIn this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera...Temperature and pressure chart for refrigerants R22, R410A, R12, R134A ... Physical and environmental properties of some common refrigerants. Refrigerants ...What are normal operating pressures for 410A mini split? The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. However, it should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load.Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.HVAC R22, 410A Refrigerants! Checking the Charge- Vapor/Suction Operating Pressures, What is Too Low! P/T Chart on the Manifold Gauge Set is …

We would like to show you a description here but the site won’t allow us.

For instance, R410a at 32⁰F saturation corresponds to a pressure of 101.6 PSI. To protect the system from freezing up, the switch setting will need to be set in and around 101.6 PSI. When speaking in regards to refrigeration, the low pressure switch is usually set up to shut down the system when it reaches set point or after a pump down .OPERATING PRESSURE POINTS "Systems using R-410A operate at higher pressures [than R-22]," points out the Field Diagnostics team. "For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ...What is the suction pressure of a Mitsubishi R410a? Normally R-22 operating system typically have a high-side (discharge) pressure of 260 psig and low-side (suction) pressure of 76 psig, while a normally R-410A operating system have a high-side (discharge) pressure of 418 psig and low-side (suction) pressure of 130 psig at 45°F/7.2℃.r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold.These units use R-410A refrigerant which operates at 50 to 70% higher pressures than R-22. Use only R-410A approved service equipment. Refrigerant cylinders are painted a “Rose” color to indicate the type of refrigerant and may contain a “dip” tube to allow for charging of liquid refrigerant into the sys-tem.Apr 5, 2020 · What is normal pressure for 410A? A normally operating R-410A system with the same condensation temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side pressure of 418 psig and a low side pressure of 130 psig. The high pressure refrigerant flows to the condenser by way of the “Discharge Line”. The condenser changes the high pressure refrigerant from a high temperature vapor to a low temperature, high pressure liquid and leaves through the “Liquid Line”. What are normal 410A operating pressures?

Longmire mt rainier weather.

Adkisson auction.

Generally, you will see normal superheat (8°-14°) on a system with heat mode TXV, and the subcooling will generally be a bit higher than usual, especially when measured outside. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system.What should my normal operating pressures on 410a systems be? R410a suction pressure may be around 120psi, and R410a head pressure may be anywhere from 225psi to 350psi. Many conditions could apply here, there’s absolutely ‘no’ set point pressure for 410a, r22, or anything else. Educate yourself on whats going on in the heat transfer process.Temperature and pressure chart for refrigerants R22, R410A, R12, R134A ... Physical and environmental properties of some common refrigerants. Refrigerants ...They recorded a 245 psi Head pressure and 115 suction pressure on my installation receipt. He also wrote "10 degrees subcool" on the receipt, which I don't see how that is possible when a 245 psi equals 83 degrees on an R-410a P/T chart. The small, copper liquid line (when measured near the compressor valve) doesn't seem to heat up …It can be used for recharging refrigerant, or to diagnose an a/c system based on pressure readings from your gauges. Ambient Temperature (°F) Low Side. High Side. 110°. 50-55 psi. 335-345 psi. 105°. 50-55 psi.Jan 15, 2023 · What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. What is the normal discharge ... Physical Properties Of R22. In parallel to using the R22 PT chart, professionals will usually need to know some of the following R22 physical properties: R22 liquid density at -69°C: 1.49 g/cm 3. R22 gas density at 15°C: 3.66 kg/m 3. Triple point temperature: -115.76K. Critical pressure: 49.36 bar. Heat capacity ratio at 86°F: 1.178253. Typical Low Side Pressure Range for R410A in the field: 115-120 psi. Typical High Side Pressure Range for R410A in the field: 410-420 psi. By 2025, high Global Warming Potential (GWP) refrigerants with a GWP of over 750, will be banned together with the systems using that gas. R410A has a GWP > 2,000. OPERATING PRESSURE POINTS "Systems using R-410A operate at higher pressures [than R-22]," points out the Field Diagnostics team. "For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ... ….

86°F. Any Tecumseh compressor with the letter “C” in the Model Number (Example: AWG5528CXD) is approved for use with R407C. shown in Figure 1. properties of R407C and R22. The data is taken at the standard refrigerant conditions of 5°F (-15°C) evaporating or 86°F (+30°C) condensing. The main reasons your compressor will have simultaneously low head pressure and high suction pressure is due to: Bad or leaky compressor valves. Worn compressor piston rings. Leaky oil separator return line. Your compressor valves may become inefficient due to poor sealing from dirt and debris deposits.Looking for normal operating pressure/temps for r-410. 14.5 seer, 2.5t new unit. 83deg outside, system was running @ 255# high side, 135#low side, liquid line temp was 84deg. Suction line temp was 64deg. I know these pressures are low, can unit be ran until weekend is over? I think undercharged? At the time house thermostat was at 78deg. Inside and set for 72 deg. Temp coming out of register ...R22 alternative names: CHClF 2 Chlorodifluoromethane, Difluoromonochloromethane, generic term: hydrochlorofluorocarbon (HCFC) R22 boiling point: -40.8 degree Celsius at atmospheric pressure (sea level or 1 ATM) R22 density: 3.66 g/cm 3, in gas form - this is a colorless gas. R22 molar mass: 86.47 g/mol.R-410A Liquid Pressure R-427A Liquid Pressure R-427A Vapor Pressure R-407A Liquid Pressure R-407A Vapor Pressure R-123 R-12 R-134a R-409A Liquid Pressure R-409A Vapor Pressure R-401A Liquid Pressure R-401A Vapor Pressure R-401B Liquid Pressure R-401B Vapor Pressure Sat. Temp (°C)-50 6.2 2.9 11.4 5.3 3.8 11.9 0.8 9.0 29.2 15.4 …Use a pressure conversion chart to change the high side pressure to saturated temperature. Deduct the liquid-line temperature from the saturation temperature of R-410A refrigerant in the condenser to compute the sub-cooling value. On the manufacturer's data sheet find the correct operating pressures for the circumstances …Consider the refrigerant R-410A: the pressure in the evaporator is 93.2 psia, according to the Table 8 (ASHRAE, 2013). The pressure value is used to find the saturation temperature. ... a lower temperature in the pipes means that the moisture contained in the air is going to freeze even if we have a normal airflow supplied by the blower. Even ...An R-22 evaporator running at 40F saturation temperature will have a corresponding pressure of 68.5 psig. Should the suction pressure drop below 57 psig, the coil temperature will drop below 32F causing moisture in the air to freeze on it (see Figure 4) causing no end of trouble. A R-410A evaporator running below 100 psig will freeze-up just ...We will first examine the low-pressure side of the system, otherwise known as the vapor or suction line. During air conditioning mode, the pressure on the vapor line of an R-410A system will be somewhere between 102 to 145 PSIG. If the system had R-22, the vapor pressure would be between 58 to 85 PSIG but these pressures will be dependent on ...They recorded a 245 psi Head pressure and 115 suction pressure on my installation receipt. He also wrote "10 degrees subcool" on the receipt, which I don't see how that is possible when a 245 psi equals 83 degrees on an R-410a P/T chart. The small, copper liquid line (when measured near the compressor valve) doesn't seem to heat up … Normal 410a pressures, Constants for vapor pressure of saturated vapor (dew point), p g: A = –1.440004 E+00 E = –3.521484 E+00 B = –6.865265 E+00 F = –7.750000 E+00 C = –5.354309 E–01 X o = 2.086902 E–01 D = –3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ..., Product Information. FreonTM 410A is a non-ozone depleting high efficiency hydrofluorocarbon (HFC) refrigerant. FreonTM 410A has higher cooling capacity and …, R-410A is considered to be a more efficient refrigerant than R-22 because it helps HVAC equipment achieve higher SEER ratings. Additionally, R-410A has higher thermodynamic and transport properties making it more efficient in the refrigeration system than R-22. Therefore, this gives R-410A a higher refrigeration capacity than R-22. , R410A PRESSURE-TEMPERATURE CHART Saturation Pressure-Temperature Data for R410A (psig)* ECLPC-1 Rev 1 - 02/22. Created Date: 2/25/2022 1:24:53 PM ..., by ziauddin khan khan , Electrical and supervisor , Majal Service Company. …See more. hi, anyone familar with R410A. For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 ..., May 26, 2012 · It is stamped 4lbs 15oz. for the manufactures charge of 410A. 4. Last check by the tech from the company that installed it before going out of warranty was High side 275 psi, high side temp 70F, Low side psi was 115 Low side temp 50. This calculates to Super Heat of 12 more or less. , Certified HVAC Technician/... 38 satisfied customers. I have a Goodman electric heat pump. 1. When set to cool, I have a Goodman electric heat pump. 1. When set to cool, the indoor status blinks for normal operation (2 seconds on and 2 seconds off) 2. When set to … read more., What are normal pressures for R410A? 00:00 - What are normal pressures for R410A? 00:37 - Can you pump down a 410A system? 01:04 - What should my …, Our Ebook, Paperback, Workbook, Quick Cards: https://www.acservicetech.com/the-book This video is on Normal Operating Pressures are for Freon R22 and R410A R..., Normal R-22 systems operate with high pressure of about 260 psi at 120° temperature and low pressure of about 76 psi at 45° evaporator temperature. R-410A. R-410 is also known as "Puron." This refrigerant is recommended for use in new residential AC units., We would like to show you a description here but the site won’t allow us., Digital Fieldpiece Gauges: https://amzn.to/2LFjNnKR410A Equipment: https://amzn.to/2xv6AG5My Favorite Tool: https://amzn.to/3NIFJuOTools We Recommend: https:..., Normal blood pressure for both men and women age 20 and older is 120/80, according to the American Heart Association. Around one out of three adults in the United States suffers from high blood pressure., When operated at a 35 degC ambient temperature, the suction pressure of an Air-Conditioner with R410A refrigerants ranges from 115 to 125 Psig. At these operating conditions, the discharge pressure is around 400 Psig. R-410A operates at 50 to 70% higher pressures than the R-22., The result is higher than normal suction pressure. ... 16427 N. Scottsdale Road #410, Scottsdale, AZ 85254 (602) 698-4432. SHOWROOM HOURS . Mon – Fri 9 am – 4:30 pm. WE ARE LICENSED CONTRACTORS. R39-R A/C & Refrig. #326306 R37 Plumbing ROC #326384 . REGISTRAR OF CONTRACTORS, high and low side pressures that are much higher when using R-410A. A typical R-22 system operating normally with a head pressure of 260 psig at a 120-degree condensing temperature and a low side pressure of 76 psig at a 45-degree evaporator saturation temperature will find the equivalent pressures in a R-410A system to be much higher., Saturation Pressure-Temperature Data for R410A (psig)* *Red Italics Indicate Inches of Mercury Below Atmospheric Pressure, In this HVAC Training Video, I show the R-22 and R-410A Range of Operating Pressures on Air Conditioning Systems! I show why we Measure Pressures and Tempera..., Check Pages 1-2 of normal refrigerant pressures for 404a ice machine in the flip PDF version. normal refrigerant pressures for 404a ice machine was published by Inez Powers on 2018-06-20. ... R-410A is potentially the most efficient refrigerant atmedium-temperature conditions (0 to 30 degrees F)., May 16, 2002 · OPERATING PRESSURE POINTS “Systems using R-410A operate at higher pressures [than R-22],” points out the Field Diagnostics team. “For example, to produce an evaporating temperature of 40 degrees F and a condensing temperature of 115 degrees, the suction and head pressures would be 83 psia and 257 psia in an R-22 system, while they would be 133 and 406 psia, respectively, in an R-410A ... , What are normal operating pressures for 410A at 90 degrees? A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side pressure of 418 psig and a low side pressure of 130 psig., Jun 7, 2021 · r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold. , 8 jul 2010 ... These pressure values are typical, but may vary due to application. Evaporator load (indoor coil in cooling mode/outdoor coil in heating mode) ..., What are normal operating pressures for 410A at 90 degrees? A normally operating R-410A system with the same condensing temperature of 120 degrees and a 45 degree evaporator saturation temperature will have a high side pressure of 418 psig and a low side pressure of 130 psig., Liquid charging will allow the ingredients to mix in the proper proportions. The operating pressures with R-410A are higher than R-22. Typical head pressure will be somewhere in the 275 to 375 psi range, while suction will be in the vicinity of 150 psi. All R-410A systems use an expansion valve at the indoor coil., r410a high/low pressures. Residential 410a system as follows: Liquid line: ~400psi. ~ 30 subcool. Vapor line: 105psi. ~30 superheat. The LLFD does not feel cold., What is the normal suction pressure and discharge pressure of or freon R22 compressor. With 90 F outdoor temperature and 79 F indoor temperature you can expect a 120 F condensing temperature, (ambient plus 30). 90 F + 30 F = 120 F ; Convert temperature to pressure, R 22 at 120 F = 260 psi ; Indoor temperature (70 F) minus 40 F …, Although it's really impossible to say what the "normal operating pressures" are for an R410A system as it's based on so many variables:load, humidity, condition of outdoor coil (clean or dirty), I would expect to see 120-135 on the low side and about 280-300 on the high side. Again, these are just examples., The low side pressure will be lower than normal. This indicates the refrigerant absorbed too much heat while traveling through the evaporator. Over Charge- If refrigerant charge is high, the superheat will be low. The low side pressure will be higher than normal. This indicates the refrigerant did not absorb enough heat to properly change to a ..., R-410A 32/125 (50/50) A1 0.2 POLYOLESTER HFC blend; higher pressures, new equipment only. R-422B 125/134a/600a (55/42/3) A1 5 MINERAL OIL or ALKYLBENZENE, POE It can replace R22, R417A and R407C with existing oil in system High Ambient and Centrifugal Chillers R-124 100 A1 0 MINERAL OIL or ALKYLBENZENE Similar to R-114 - high ambient air ..., Jul 4, 2015 · Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation. , Freon™ 407A are shown in Table 3. The pressure-enthalpy diagrams for Freon™ 407C are shown in Figures 1 and 2. Additional physical property data may be found in other Chemours publications. Thermodynamic properties booklets are also available for Freon™ 407C and Freon™ 407A in both English and metric units. Transport properties, Check Pages 1-2 of normal refrigerant pressures for 404a ice machine in the flip PDF version. normal refrigerant pressures for 404a ice machine was published by Inez Powers on 2018-06-20. ... R-410A is potentially the most efficient refrigerant atmedium-temperature conditions (0 to 30 degrees F).